Lenntech engineers design and build tailor-made ultrafiltration plants.
Our UF plants are build with hollow fiber outside-in membranes, up to 100 m3/h, to purify surface or groundwater from suspended solids, colloids and all kind of micro-organisms such as bacteria, virus, protozoa, germs and larvae.
Ultrafiltration is also commonly use as a Reverse Osmosis plant pretreatment.
Check Lenntech UF pilot for rent.
Turnkey and tailor made UF plants can be build for industrial applications.
Ultrafiltration plant description.
General design data for Ultrafiltration Plants:
|
Groundwater |
Seawater |
Surface water |
Turbidity |
< 5 NTU |
< 20 NTU |
< 50 NTU |
Flux |
75 lmh |
60 lmh |
45 lmh |
Daily recovery (24h) |
96% |
94% |
85% |
Membrane types |
Hollow fiber outside-in |
Max TSS |
100 mg/L |
Max COD |
60 ppm |
Max oil and grease |
2 ppm |
What is ultrafiltration?
Seawater desalination
Surface water treatment
Ultrafiltration membranes |